ON005931: ieeg dataset, 8 subjects#
Visuomotor_task
Access recordings and metadata through EEGDash.
Citation: Riyo Ueda, Eishi Asano (2026). Visuomotor_task. 10.82901/nemar.on005931
Modality: ieeg Subjects: 8 Recordings: 16 License: CC0 Source: nemar
Metadata: Complete (100%)
8-participant iEEG dataset — Visuomotor_task.
Quickstart#
Install
pip install eegdash
Access the data
from eegdash.dataset import ON005931
dataset = ON005931(cache_dir="./data")
# Get the raw object of the first recording
raw = dataset.datasets[0].raw
print(raw.info)
Filter by subject
dataset = ON005931(cache_dir="./data", subject="01")
Advanced query
dataset = ON005931(
cache_dir="./data",
query={"subject": {"$in": ["01", "02"]}},
)
Iterate recordings
for rec in dataset:
print(rec.subject, rec.raw.info['sfreq'])
If you use this dataset in your research, please cite the original authors.
BibTeX
@dataset{on005931,
title = {Visuomotor_task},
author = {Riyo Ueda and Eishi Asano},
doi = {10.82901/nemar.on005931},
url = {https://doi.org/10.82901/nemar.on005931},
}
About This Dataset#
Dataset of intracranial EEG from human epilepsy patients performing a visuomotor task
Description:
We present an electrophysiological dataset recorded from ten subjects during a visuomotor task. Subjects were epilepsy patients undergoing intracranial monitoring for localization of epileptic seizures. Subjects completed five sessions of Speed Match - a visuomotor on the Lumosity platform (https://www.lumosity.com/; Lumos Labs, Inc, San Francisco, CA) - during interictal EEG recording.
Repository structure:
Main directory (interictal EEG from children during gameplay): Contains interictal EEG files of each participant in the study. Folders are explained below.
Subfolders: sub-/: Contains folders for each subject, named sub-. sub-/ses-: Contains folders for visuomotor task. sub-/ses-/ieeg/: Contains the raw iEEG data in .edf format for each subject. Each subject performed visuomotor task (ses-task). Each *ieeg.edf file contains continuous iEEG data during the visuomotor task. Details about the channels are given in the corresponding .tsv file. We also provide the information on the timing of the finger tapping on ieeg/edf file by specifying the start and end sample of each trial. (101 is for finger tapping).
Channel names follow the data headers (18 Oct 2026)
In 16 recordings the channel list of channels.tsv did not equal the data-file header (names, order or count). In the 16 with a different channel count, mne_bids.read_raw_bids warned and kept the header names, so the channels.tsv types and bad-channel status reached only the channels whose names happen to be identical; a reader that applies the channels.tsv rows by position gives wrong labels wherever the two lists are not aligned. Since 18 Oct 2026 every channels.tsv lists exactly the header channels, in header order, with the header names (MNE names: duplicated header labels numbered -0, -1).
Rows were matched to header channels BY NAME, never by position (exact; then case/whitespace; then the recorder prefix ‘EEG ‘/’POL ‘, ‘_’ and zero padding; then a trailing ‘-<reference>’ token). Matched rows keep all their columns (type, units, status, …); 990 rows took the header name (the header labels carry ‘POL ‘ prefix + ‘-AV’ suffix).
990 channels.tsv rows had no channel in the data file (16 files) and were removed; they are kept verbatim under sourcedata/channels-removed-2026-10-18/ (same relative path). Examples: sub-01_ses-01_task-game_run-01_ieeg.edf: B1, B10, B11, B12, B13; sub-01_ses-02_task-game_run-01_ieeg.edf: A1, A10, A11, A12, A13; sub-02_ses-01_task-game_run-01_ieeg.edf: B1, B10, B11, B12, B13.
16 files listed the channels in another order than the header; rows now follow the header order.
Applied by position, the former rows would have given wrong labels to 982 channels in 16 files (rows missing, extra or out of order before that position).
electrodes.tsv is unchanged and keeps the contact names (e.g. A1), while channels.tsv follows the recording headers (e.g. POL A1, EEG M2-Ref). To pair a channel with its contact, drop a leading POL `` or ``EEG `` and a trailing reference suffix (-Ref``, -AV).
Electrode locations (19 Oct 2026)
Add coordsystem.json fsaverage/mm next to 16 electrodes.tsv. Evidence: Wayne State (Asano/Kanno/Kochi) deposits use FreeSurfer-standard (MNI305/fsaverage) electrode coordinates; MNI305 is a millimetre space by definition. No OpenNeuro S3 version of this dataset ever held a coordsystem.json (all versions listed 2026-10-19). Paper PMC12829438 (section 2.2): FreeSurfer used “to normalize each electrode site to a Montreal Neurological Institute (MNI)-standard brain coordinate” (FreeSurfer’s MNI space is MNI305); the coordinates are identical (within 0.001 mm) in 12 of the 16 files to ds006233 (README MNI-305) and 8 to on007119 (fsaverage / mm). Every contact of the 16 files (1724 in all) lies on a vertex of the fsaverage pial surface (within 0.001 mm), so the frame is labeled fsaverage.
This dataset mirrors OpenNeuro; the same change belongs upstream.
Cohort#
Dataset Statistics#
Age distribution by gender (n=8, range 9–20 yr, mean 15.0 yr)
Sex composition
Channel counts (ch)
Sampling frequencies: 1000.0 Hz (n=16 recordings)
Total recording duration: 1 h 53 min
Signal · Electrodes & live trace#
Live trace viewer — sub-04 · ses-02 · task-game · run-01
Showing one representative recording out of
8 subjects and 16 recordings in this dataset.
Browse the full set on OpenNeuro;
drop any other _ieeg.{set,edf,bdf,vhdr} file onto the
viewer (or pass ?ieeg=<url>) to inspect it.
Electrode layout — iEEG · 106 sensors — 106 channels
NEMAR Processing Statistics#
The plots below are generated by NEMAR’s automated EEG pipeline. The histogram shows pipeline success for data cleaning and ICA decomposition, the percentage of data frames and EEG channels retained after artefact removal, line noise per channel (RMS, dB), and the age/gender distribution of participants.
HED event descriptors word cloud
Manifest#
File Explorer#
Browse the BIDS file structure of this dataset. Records are fetched on demand from the EEGDash catalog the first time you open the explorer.
Full dataset metadata table
Dataset ID |
|
Title |
Visuomotor_task |
Author (year) |
— |
Canonical |
— |
Importable as |
|
Year |
2026 |
Authors |
Riyo Ueda, Eishi Asano |
License |
CC0 |
Citation / DOI |
|
Source links |
OpenNeuro | NeMAR | Source URL |
Copy-paste BibTeX
@dataset{on005931,
title = {Visuomotor_task},
author = {Riyo Ueda and Eishi Asano},
doi = {10.82901/nemar.on005931},
url = {https://doi.org/10.82901/nemar.on005931},
}
API Reference#
eegdash.datasetEEGDashDataset- class eegdash.dataset.ON005931(cache_dir: str, query: dict | None = None, s3_bucket: str | None = None, **kwargs)[source]#
Visuomotor_task
- Study:
on005931(NeMAR)- Author (year):
—
- Canonical:
—
Also importable as:
ON005931.Modality:
ieeg; Experiment type:Motor; Subject type:Epilepsy. Subjects: 8; recordings: 16; tasks: 1.- Parameters:
cache_dir (str | Path) – Directory where data are cached locally.
query (dict | None) – Additional MongoDB-style filters to AND with the dataset selection. Must not contain the key
dataset.s3_bucket (str | None) – Base S3 bucket used to locate the data.
**kwargs (dict) – Additional keyword arguments forwarded to
EEGDashDataset.
- data_dir#
Local dataset cache directory (
cache_dir / dataset_id).- Type:
Path
Notes
Each item is a recording; recording-level metadata are available via
dataset.description.querysupports MongoDB-style filters on fields inALLOWED_QUERY_FIELDSand is combined with the dataset filter. Dataset-specific caveats are not provided in the summary metadata.References
OpenNeuro dataset: https://openneuro.org/datasets/on005931 NeMAR dataset: https://nemar.org/dataexplorer/detail?dataset_id=on005931 DOI: https://doi.org/10.82901/nemar.on005931
Examples
>>> from eegdash.dataset import ON005931 >>> dataset = ON005931(cache_dir="./data") >>> recording = dataset[0] >>> raw = recording.load()
- __init__(cache_dir: str, query: dict | None = None, s3_bucket: str | None = None, **kwargs)[source]#
- save(path: str, overwrite: bool = False, offset: int = 0)[source]#
Save datasets to files by creating one subdirectory for each dataset:
path/ 0/ 0-raw.fif | 0-epo.fif description.json raw_preproc_kwargs.json (if raws were preprocessed) window_kwargs.json (if this is a windowed dataset) window_preproc_kwargs.json (if windows were preprocessed) target_name.json (if target_name is not None and dataset is raw) 1/ 1-raw.fif | 1-epo.fif description.json raw_preproc_kwargs.json (if raws were preprocessed) window_kwargs.json (if this is a windowed dataset) window_preproc_kwargs.json (if windows were preprocessed) target_name.json (if target_name is not None and dataset is raw)
- Parameters:
path (str) –
- Directory in which subdirectories are created to store
-raw.fif | -epo.fif and .json files to.
overwrite (bool) – Whether to delete old subdirectories that will be saved to in this call. If a dataset still reads its data lazily from one of them, a
ValueErroris raised before anything is deleted: load the data into memory first (preload=True) or save to another directory.offset (int) – If provided, the integer is added to the id of the dataset in the concat. This is useful in the setting of very large datasets, where one dataset has to be processed and saved at a time to account for its original position.
BaseDataset from braindecode — windowed via create_windows_from_events.braindecodeDataLoader; supports parallel workers and on-the-fly augmentations.pytorchSwap any load_dataset(...) call for on005931 to reproduce the tutorial on this dataset.
Citation
Riyo Ueda, Eishi Asano (2026). Visuomotor_task. 10.82901/nemar.on005931
Provenance
¹Contributed to nemar in BIDS format.
²Curated & ingested by the EEGDash catalog; see CITATION.cff for canonical reference.
³Persistent identifier: 10.82901/nemar.on005931.
See Also#
eegdash.dataset.EEGDashDataseteegdash.dataset